  1. GENERAL DESCRIPION
    1.1 Type No. : UC-027
    1.2 Customer P/N :
  2. DESCRIPTION & APPLICATION
    This antenna assembly is designed for use in portable. Communications equipment over a temperature range. Of -20 ℃ to +85 ℃ in an indoor / outdoor environment.
  3. ELECTRICAL CHARACTERISTICS
    3.1 Frequency Range : 890~960 & 1710~1880 MHz
    3.2 V.S.W.R : ≦ 1.5
    3.3 Connector : SMA Male
    3.4 Impedance : 50 Ω
  4. ENVIRONMENTAL CHARACTERISTICS
    4.1 Operating temperature range -20 ℃ to +85 ℃
    4.2 Humidity range : 10 % RH to 80 % RH
  5. QUALIFICATION TESTING
    5.1 Qualification testing, all product shall be able to withstand the following testing.
    5.2 Physical dimensions identified within this specification.
    5.3 Pull Test : Tube has the capability of load 3 kgf in a vertical position within 30 seconds.
    5.4 Torque Test : 3 kgf-cm no damage happened.
  6. INSPECTION STANDARD
    6.1 Dimension to use the special inspection level of S-4 , AQL 1.0 .
    6.2 Appearance to use MIL-STD-105DII AQL1.0 .
    6.3 Mechanical Capability : Per lot Sampling, n=5 , Ac 0 , Re 1 .
    6.4 Environmental test : Per lot Sampling, n=3 , Ac 0, Re 1 .
  7. PACKING STYLE
    If customer has no specific request by the customer, all according to our standard Packing specification.
  8. OTHERS
    Any changes in this specification should be agreed by both parties.

Electrical Specification

Frequency range

890~960 & 1710~1880 MHz

V.S.W.R

≦ 1.5

Connector

SMA Male

Impedance

50Ω

 

 

Environmental & Mechanical Characters

Temperature

-20 ℃ to +85 ℃

Weight

9.0 g

Dimensions

16.5x52.0 mm

TEST REPORT

1.MODEL:

UC-027

2.QUANTITY:

5 Pcs

3.DATE OF TESTING:

Mar.29,2004

4.TESTING ITEM:

PULL TEST

5.TESTING EQUIPMENT:

B-016 (PUSH-PULL SCALE FB30K)

6.TESTING CONDITIONS:

Antenna must withstand a 3 kgf tensile

 

Load applied to tube for 30 seconds.

 

No part of the antenna may be pulled out of

 

The assembly or from the housing.

 
7.TESTING RESULT:

SAMPLE

1

2

3

4

5

OKor NG

OK

OK

OK

OK

OK

DEPT.MANAGER: TESTER
TEST REPORT

1.MODEL:

UC-027

2.QUANTITY:

5 Pcs

3.DATE OF TESTING:

Mar.29,2004

4.TESTING ITEM:

TORQUE TEST

5.TESTING EQUIPMENT:

B-001 (MECHANICAL TORQUE METER 2-TM30)

6.TESTING CONDITIONS:

3 kgf-cm no damage happened.

 
7.TESTING RESULT:

SAMPLE

1

2

3

4

5

OKor NG

OK

OK

OK

OK

OK

DEPT.MANAGER: TESTER
 

Use Link Group Co., Ltd.
Head Office (Taiwan)

11F.-6, No.432, Sec. 1, Keelung Rd., Xinyi Dist., Taipei City 110, Taiwan (R.O.C.)
TEL : 886-2-27588816   FAX : 886-2-27582006

Factory Location
THAILAND : No.9 Soi Koo Bon 31, Lane 8, Koo Bon Road,Kunnayao District , Bangkok , 10230 Thailand.
TEL : 66-2-9434052   FAX : 66-2-9434395
China : Fuhai,Cixi,Zhejiang, China

E-Mail : fkkchang@seed.net.tw ; sales@uselink.com.tw